Calibrations & Certifications
Checks & Calibrations
Operational Checks
This is not a calibration. An ‘Operational Check’ will evaluate the performance and/or accuracy of equipment using tools and instrumentation of known standard or reference. A field service report will be provided offering a basic summary of findings. If the equipment does NOT appear to meet specification and repairs, adjustments, or calibration are needed, additional charges may apply.
Standard Calibration
Everything from an ‘Operational Check’, and we use OEM recommended and laboratory-developed calibration procedures to calibrate the equipment. A calibration sticker with the next calibration due date gets affixed to the equipment. If the equipment does NOT meet specifications and/or repairs are needed, additional charges may apply.
ISO 17025 Accredited Calibration
Everything from a ‘Documented Calibration’ as well as uncertainty data. The calibration report will include our accreditation body’s logo and certificate number. If the equipment does NOT meet specifications and repairs are needed, additional charges may apply.
Documented Calibration
Everything from a ‘Standard Calibration’ as well as a calibration report /certificate documenting all traceable test equipment and data point readings. If the equipment does NOT meet specification and repairs are needed, additional charges may apply.
Confidentiality: All pricing, terms and conditions of any service agreements or estimates are absolutely confidential between Tritech and the customer and shall not be disclosed to any other parties except as may be necessary to execute agreement terms. Any disclosure, copying, or distribution of its contents are strictly prohibited.
How Our Calibrations Work
Type of Service
Operational Check
Standard Calibration
Documented Calibration
Accredited Calibration
Field service report summarizing findings.
Verify device operation using NIST-traceable equipment and tools
Device adjustment if found out of tolerance
Calibration sticker affixed to machine
Calibration report/certificate
Data points including “as found” and “as left”
Logo from accreditation body and certification number
Testing conditions (temp, humidity, barometric pressure) included in report
Expanded measurement uncertainty are recorded on report/certificate
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Our Fume Hood Certification
We have expanded our calibration services to include fume hood certification. Typically, laboratory fume hoods are tested annually. Our testing includes the following.
General Cabinet Integrity Inspection
Visual inspection of the fume hood, including general condition, checking for flow gauge, alarms, sash, and baffle function.
Test & Certify Face Velocity Airflow
Fume hood performance testing through face velocity measurements using a calibrated thermal anemometer (air velocity meter) and procedure as outlined by ANSI/ASHRAE 110-2016.
Using smoke tubes and procedure as outlined by ANSI/ASHRAE 110-2016.
Test & Certify Airflow Visualization
Certification Sticker & Report
Fume hood testing certification sticker with system identifying information and data. Report that contains a through breakdown of inspection points, tests, data points, and findings during a fume hood certification.